Mint NextMove PCI Instrukcja Użytkownika Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 56
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
31
Typical Connections
W INPUT CHARACTERISTICS
Opto-isolated and may be connected to positive or
negative common (for use with NPN and PNP output
transistors).
E FAST POSITION CAPTURE
One of the 4 FASTPOS inputs will latch selected axis
position data within 25µS. The remaining 3 FASTPOS
inputs latch data within 1ms.
R HOME
One per axis, taken from the 16 digital inputs.
Provides reference position for the axis.
Three modes of homing: on encoder index, on switch,
on both.
Y DRIVE ERROR INPUT
Usually one per controller, taken from the 16 digital
inputs. Brings all axes to a crash stop when active.
Input sense software configurable.
U ANALOG INPUTS
8 x 12 bit resolution single
ended inputs or
4 x 12 bit resolution,
differential inputs.
±10V, ±5V, 0-10V or 0-5V
voltage ranges can
be set by the user.
T LIMIT
One or two per axis, taken from the 16 digital inputs.
Provides end of travel protection. Crash stop assigned
axes when active.
Q DIGITAL INPUTS
16 digital inputs, user configured for limit, home, stop,
error or general purpose.
May be configured as level or edge triggered, and
to interrupt a user program and call a subroutine.
1
4
5
4
5
¨ ¨
1
7
8
9
1 0
1 0
3
1 0
1 0
1 1
1 3
1 4
1 5
1 7
Przeglądanie stron 16